Media 000058004: Full Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000058004
Media type
Volumetric Image Series
Object element or part
full body
Object represented
Object taxonomy
Pan troglodytes
Side
NotApplicable
Orientation
--
Short description
Zipped dicom stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped dicom stack Migrated MorphoSource 1 Media Group Title: medical CT volume and derivatives Migrated MorphoSource 1 Media File Description: correct chirality Migrated MorphoSource 1 Media Group Description: correct chirality
Creator
--
Date created
--
Date uploaded
September 17, 2018

FILE OBJECT DETAILS Field Definitions

File name
YPM-015939full-body.zip
File format(s)
ZIP archive, DICOM
File size
364 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.976562
Y pixel spacing
0.976562
Z pixel spacing
0.625000
Pixel spacing units
Mm
Slice thickness
0.625000
Number of images in set
1,779

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric Discovery NM/CT 570c, Yale Translational Research Imaging Center (Y-TRIC) (Yale University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Yale University
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
BCS-1552848); NSF (DBI-1701769; DBI-1701714
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Greg Watkins-Colwell provided access to these data , the collection of which was funded by NSF (DBI-1701769. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object YPM:VZ:YPM MAM 015939 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Yale Translational Research Imaging Center (Y-TRIC) (Yale University)
Creator
Doug Boyer, Attila Feher, and Nabil Boutagy
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
nr
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
nr
Projections
nr
Voltage
120
Power
0.0
Amperage
nr
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000058004: Full Body [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Doug Boyer, Attila Feher, and Nabil Boutagy
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000058004: Full Body [CTImageSeries] [Etc] (this media)