Media 000115331: Right Labyrinth
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000115331: Right Labyrinth
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000115331
Media type
Mesh
Object element or part
Right Labyrinth
Object represented
Object taxonomy
Velociraptor mongoliensis
Object organization
Side
Right
Orientation
--
Short description
IGM 100/976 Right Labyrinth
Full description
Migrated MorphoSource 1 Media File Title: IGM 100/976 Right Labyrinth Migrated MorphoSource 1 Media Group Title: Braincase and Endocranial STL models
Creator
--
Date created
--
Date uploaded
April 30, 2020
FILE OBJECT DETAILS Field Definitions
File name
Right_labyrinth.stl
File format(s)
STL
File size
11.6 MB
Points
122043
Polygons
244094
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
11.161, 23.263, 14.412
Centroid coordinates
52.416, 48.582, 20.422
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
American Museum of Natural History
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
Leverhulme Trust (ECF-2017-360)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: James Neenan and colleagues provided access to these dataoriginally appearing in King et al. 2020. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
igm:MAE:100/976
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert and Rachel Racicot
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
210
Power
--
Amperage
110
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000115331: Right Labyrinth [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Matthew Colbert and Rachel Racicot
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000115331: Right Labyrinth [Mesh] [Etc] (this media)