Media 000393231: Right Radius
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000393231
Media type
Mesh
Object element or part
right radius
Object represented
Object taxonomy
Navajosphenodon sani
Object organization
Side
--
Orientation
--
Short description
--
Full description
3D model of the right radius of Navajosphenodon sani (MNA.V.12442, previously MCZ VPRA-9016).
Creator
Tiago Simoes
Date created
March 11, 2020
Date uploaded
October 29, 2021

FILE OBJECT DETAILS Field Definitions

File name
MNA.V.12442_Navajosphenodon_sani_Radius_Right.stl
File format(s)
STL
File size
265 KB
Points
2717
Polygons
5426
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
2.483, 5.919, 0.942
Centroid coordinates
18.398, 20.454, 9.030
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225, Center for Nanoscale Systems (Harvard University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Museum of Northern Arizona
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object mna:v:12442 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Center for Nanoscale Systems (Harvard University)
Creator
Tiago Simoes
Event date
August 15, 2019
Software
--
Description
CT TIFFs of full specimen
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
708
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
--
Projections
3142
Voltage
90
Power
14490
Amperage
161
Surrounding material
--
X-ray tube type
--
Target type
Reflection
Detector type
--
Detector pixels X
--
Detector pixels size X
.2
Detector pixels Y
--
Detector pixels size Y
.2
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000391921: Skeleton [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Tiago Simoes
Event date
August 15, 2019
Software
VGStudio MAX CT Reconstruction Module
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
Description

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000391921: Skeleton [CTImageSeries] [CT] was processed with 1 activity to create derived Media 000393231: Right Radius [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Tiago Simoes
Event date
March 11, 2020
Software
MIMICS v.22
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
Description

Media produced by this event on MorphoSource

Media 000393231: Right Radius [Mesh] [CT] (this media)