Media 000417484: Cranium
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000417484
Media type
Volumetric Image Series
Object element or part
Cranium
Object represented
Object taxonomy
Trinitichelys hiatti
Object organization
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
September 25, 2020
Date uploaded
January 27, 2022

FILE OBJECT DETAILS Field Definitions

File name
Trinitichelys_hiatti_MCZ_VPRA_4070_scans.zip
File format(s)
ZIP archive, TIFF
File size
2.9 GB
Image width
2240
Image height
224
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.029184
Y pixel spacing
0.029184
Z pixel spacing
0.029184
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,210

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Museum of Comparative Zoology Scanning Facility (Harvard University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCZ:VP:VPRA-4070 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Museum of Comparative Zoology Scanning Facility (Harvard University)
Creator
--
Event date
September 25, 2020
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
350 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
25
Projections
--
Voltage
130
Power
--
Amperage
60
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2240
Detector pixels size X
0.292
Detector pixels Y
2240
Detector pixels size Y
0.292
Detector configuration
--
Source object distance
212.338 mm
Source detector distance
364 mm
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000417484: Cranium [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
Description

Media produced by this event on MorphoSource

Media 000417484: Cranium [CTImageSeries] [CT] (this media)