Media 000430197: Supraoccipital
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000430197: Supraoccipital
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000430197
Media type
Mesh
Object element or part
Supraoccipital
Object represented
Object taxonomy
Trinitichelys hiatti
Object organization
Side
Midline
Orientation
--
Short description
--
Full description
--
Creator
Yann Rollot
Date created
March 10, 2022
Date uploaded
March 10, 2022
FILE OBJECT DETAILS Field Definitions
File name
Supraoccipital_Trinitichelys_hiatti_MCZ_4070.ply
File format(s)
PLY
File size
23.1 MB
Points
326432
Polygons
649526
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
11765.199, 11348.500, 21234.780
Centroid coordinates
31648.511, 25588.653, 16424.774
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(1 step)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Museum of Comparative Zoology Scanning Facility (Harvard University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
MCZ:VP:VPRA-4070
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Museum of Comparative Zoology Scanning Facility (Harvard University)
Creator
--
Event date
September 25, 2020
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
350 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
25
Projections
--
Voltage
130
Power
--
Amperage
60
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2240
Detector pixels size X
0.292
Detector pixels Y
2240
Detector pixels size Y
0.292
Detector configuration
--
Source object distance
212.338 mm
Source detector distance
364 mm
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 1 activity
to create
derived
Media 000417484: Cranium [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Processing Activity 1: Reconstruction
Software
Description
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000417484: Cranium [CTImageSeries] [CT]
was processed
to create
derived
Media 000430197: Supraoccipital [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Yann Rollot
Event date
--
Software
Amira
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000430197: Supraoccipital [Mesh] [CT] (this media)