Media 000634333: Skull
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000634333
Media type
Volumetric Image Series
Object element or part
Skull
Object represented
Object taxonomy
Pseudogonatodes fuscofortunatus
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
April 14, 2023
Date uploaded
June 03, 2024

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
1.66 GB
Image width
866
Image height
713
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.006180
Y pixel spacing
0.006180
Z pixel spacing
0.006180
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,712

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MBLUZ:1292 was imaged to create this media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
April 14, 2023
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.045s
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
70kV
Power
--
Amperage
8W
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
000618
Detector pixels size X
000618
Detector pixels Y
000618
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

Media 000634333: Skull [CTImageSeries] [CT] (this media)