Media 000636647: Tail
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000636647
Media type
Volumetric Image Series
Object element or part
tail
Object taxonomy
Exiliboa placata
Side
--
Orientation
--
Short description
HRXCT scan -- tail
Full description
University of Texas High-Resolution X-ray CT Facility Archive 2386 Smith: 209414B: Scans of the tail of Exiliboa placata (USNM 209414; Cerro Pelon, 5.8 mi N of, Sierra de Juarez cloud forest, Oaxaca, Mexico; Collected on 1974-06-09) for Krister Smith of the Museum und Forschungsinstitut Senckenberg. Specimen scanned by Jessie Maisano 3 February 2011. scan parameters: Xradia. 0.5X objective, 70kV, 10W, 1s acquisition time, detector 58.16 mm, source -104 mm, XYZ [4427, 23129, 3116], camera bin 2, angles ±105, 736 views, 1 mm SiO2 filter, dithering, no sample drift correction. End reference (45 frames, each for 1s). Reconstructed with center shift -2, beam hardening 0, theta 0, byte scaling [-15, 125], binning 1, recon filter smooth (kernel size = 0.8). Voxels are 36.17 microns. Total slices = 365.
Creator
Jessie Maisano
Date created
February 03, 2011
Date uploaded
June 12, 2024

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
437 MB
Image width
963
Image height
954
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.036170
Y pixel spacing
0.036170
Z pixel spacing
0.036170
Pixel spacing units
Um
Slice thickness
--
Number of images in set
365

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
Data acquired for Krister Smith. Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object usnm:Amphibians & Reptiles:209414 was imaged to create this media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Jessie Maisano
Event date
February 03, 2011
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

Media 000636647: Tail [CTImageSeries] [CT] (this media)