Media 000638360: Ear
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000638360: Ear
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000638360
Media type
Volumetric Image Series
Object element or part
ear
Object represented
Object taxonomy
Bos taurus
Object organization
Side
--
Orientation
--
Short description
HRXCT scan of the ear
Full description
University of Texas High-Resolution X-ray CT Facility Archive 2387
Kirk:
M-3959B: Scans of the ear of Bos taurus (TMM M-3959) for Chris Kirk of UT Anthropology. Specimen scanned by Jessie Maisano 17 February 2011.
scan parameters: Xradia. 0.5X objective, 100kV, 10W, 2s acquisition time, detector 155 mm, source -80.8 mm, XYZ [1996, 16616, -6881], camera bin 2, angles ±101, 809 views, 1.6 mm CaF filter, dithering, no sample drift correction. Crop-and-fill plugin applied. End reference (45 frames, each for 1.75s). Reconstructed with center shift 0.5, beam hardening 0.1, theta 0, byte scaling [-20, 75], binning 1, recon filter smooth (kernel size = 0.8). Total slices = 857.
M-3959B.rcp: Xradia recipe with scan parameters.
16bit: 16bit TIFF images reconstructed by Xradia Reconstructor. Voxels are 19.32 microns.
Creator
Jessie Maisano
Date created
February 17, 2011
Date uploaded
June 20, 2024
FILE OBJECT DETAILS Field Definitions
File name
16bit.zip
File format(s)
ZIP archive, TIFF
File size
1.15 GB
Image width
1012
Image height
1024
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.019320
Y pixel spacing
0.019320
Z pixel spacing
0.019320
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
857
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Memorial Museum
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
Data acquired for Chris Kirk. oUTCT provided access to these data, funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
tmm:mwsu:3959
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000638360: Ear [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000638360: Ear [CTImageSeries] [CT] (this media)