Media 000638365: Ear
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000638365
Media type
Volumetric Image Series
Object element or part
ear
Object represented
Object taxonomy
Canis familiaris
Side
--
Orientation
--
Short description
HRXCT scan ear
Full description
University of Texas High-Resolution X-ray CT Facility Archive 2392 Kirk: M-51A: Scans of the ear of Canis familiaris (TMM M-51) for Chris Kirk of UT Anthropology. Specimen scanned by Jessie Maisano 16 February 2011. scan parameters: Xradia. 0.5X objective, 70kV, 10W, 4s acquisition time, detector 168 mm, source -53 mm, XYZ [-3698, 3240, -4500], camera bin 2, angles ±101, 809 views, 1.4 mm SiO2 filter, dithering, no sample drift correction. Crop-and-fill plugin applied. End reference (45 frames, each for 2.5s). Reconstructed with center shift 0.5, beam hardening 0.15, theta 0, byte scaling [-20, 80], binning 1, recon filter smooth (kernel size = 0.8). Total slices = 856. M-51A.rcp: Xradia recipe with scan parameters. 16bit: 16bit TIFF images reconstructed by Xradia Reconstructor. Voxels are 13.52 microns.
Creator
Jessie Maisano
Date created
February 16, 2011
Date uploaded
June 20, 2024

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
1.12 GB
Image width
1012
Image height
1024
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.013520
Y pixel spacing
0.013520
Z pixel spacing
0.013520
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
856

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Memorial Museum
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
Data acquired for Chris Kirk. oUTCT provided access to these data, funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tmm:m:51 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000638365: Ear [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000638365: Ear [CTImageSeries] [CT] (this media)