Media 000101461: Braincase
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000101461
Media type
Volumetric Image Series
Object element or part
Braincase
Object represented
Object taxonomy
Irritator challengeri
Side
--
Orientation
--
Short description
DICOM stack of braincase
Full description
Migrated MorphoSource 1 Media File Title: DICOM stack of braincase Migrated MorphoSource 1 Media Group Title: Dicom stack of braincase Migrated MorphoSource 1 Media Group Description: We would ask you to kindly contact Marco Schade (marco.schade@stud.uni-greifswald.de) if you want to use the CT data for descriptive purposes, as we are using the scans to prepare a redescription of Irritator.
Creator
--
Date created
--
Date uploaded
February 24, 2020

FILE OBJECT DETAILS Field Definitions

File name
Irritator_challengeri_SMNS58022_Metronom_scan.zip
File format(s)
ZIP archive, DICOM
File size
11.3 GB
Image width
3138
Image height
2047
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.097130
Y pixel spacing
0.097130
Z pixel spacing
0.097130
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,410

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Metrotom 1500, Zeiss Competency Center for Car Body Measuring Technology Essingen (Carl Zeiss Industriellen Messtechnik GmbH)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
SMNS Stuttgart
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Marco Schade provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object smns:58022 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Zeiss Competency Center for Car Body Measuring Technology Essingen (Carl Zeiss Industriellen Messtechnik GmbH)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
250
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
180
Power
--
Amperage
1800
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000101461: Braincase [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000101461: Braincase [CTImageSeries] [Etc] (this media)