Media 000372286: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

Media preview currently unavailable. Please check back later.

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000372286
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Neusticemys neuquina
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Pablo González Ruiz; Marcelo de la Fuente
Date created
June 07, 2019
Date uploaded
July 26, 2021

FILE OBJECT DETAILS Field Definitions

File name
Neusticemys_neuqina_MACN-PV-105.zip
File format(s)
ZIP archive, application/octet-stream
File size
26.2 MB
Image width
--
Image height
--
Color space
--
Color depth
--
Compression
--
X pixel spacing
--
Y pixel spacing
--
Z pixel spacing
--
Pixel spacing units
--
Slice thickness
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric Lightspeed Pro 16 CT scanner, Departamento de Imágenes FUESMEN (Fundación Escuela de Medicina Nuclear (FUESMEN))

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object na was imaged to create this media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Departamento de Imágenes FUESMEN (Fundación Escuela de Medicina Nuclear (FUESMEN))
Creator
Pablo González Ruiz; Marcelo de la Fuente
Event date
June 07, 2019
Software
3D Slicer
Description
--
Description attachment
None
Reference attachment
None
Exposure time
9 minutes
Flux normalization
Yes
Pixel spacing calibration
Fiducial
Shading correction
Yes
Frame averaging
--
Projections
--
Voltage
139kV
Power
--
Amperage
140µA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
Yes
Optical magnification
No
Acquisition type
Stationary

Media produced by this event on MorphoSource

Media 000372286: Element Unspecified [CTImageSeries] [CT] (this media)