Media 000372634: Supraoccipital
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000372634: Supraoccipital
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000372634
Media type
Mesh
Object element or part
Supraoccipital
Object represented
Object taxonomy
Neusticemys neuquina
Object organization
Side
NotApplicable
Orientation
--
Short description
Supraoccipital
Full description
Supraoccipital of the N. neuquina juvenile
Creator
--
Date created
July 27, 2021
Date uploaded
July 27, 2021
FILE OBJECT DETAILS Field Definitions
File name
Supraoccipital.stl
File format(s)
STL
File size
394 KB
Points
4130
Polygons
8064
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
15.664, 9.772, 14.547
Centroid coordinates
0.401, 0.390, -54.187
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
1
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric Lightspeed Pro 16 CT scanner, Departamento de Imágenes FUESMEN (Fundación Escuela de Medicina Nuclear (FUESMEN))
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
na
was imaged to create
raw
Media 000372286: Element Unspecified [CTImageSeries] [CT].
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Departamento de Imágenes FUESMEN (Fundación Escuela de Medicina Nuclear (FUESMEN))
Creator
Pablo González Ruiz; Marcelo de la Fuente
Event date
June 07, 2019
Software
3D Slicer
Description
--
Description attachment
None
Reference attachment
None
Exposure time
9 minutes
Flux normalization
Yes
Pixel spacing calibration
Fiducial
Shading correction
Yes
Frame averaging
--
Projections
--
Voltage
139kV
Power
--
Amperage
140µA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
Yes
Optical magnification
No
Acquisition type
Stationary
Media produced by this event on MorphoSource
STEP 2: IMAGE PROCESSING
Raw
Media 000372286: Element Unspecified [CTImageSeries] [CT]
was processed
to create
derived
Media 000372634: Supraoccipital [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
3D Slicer
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000372634: Supraoccipital [Mesh] [CT] (this media)