Media 000422117: Mandible
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000422117
Media type
Mesh
Object element or part
Mandible
Object represented
Object taxonomy
Rhinodipterus kimberleyensis
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Alice Clement
Date created
February 15, 2022
Date uploaded
February 16, 2022

FILE OBJECT DETAILS Field Definitions

File name
Rhinodipterus_jaw_STL.stl
File format(s)
STL
File size
61.9 MB
Points
166469
Polygons
338187
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
8.647, 3.622, 8.334
Centroid coordinates
-0.167, 0.022, 0.187
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
2
Number of processing events
3 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Custom Make µCT Scanner Assembled In-House, National Laboratory for X-ray Micro Computed Tomography (Australian National University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object wam:palaeontology:09.6.149 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
National Laboratory for X-ray Micro Computed Tomography (Australian National University)
Creator
--
Event date
--
Software
Drishti
Description
The Australian National University (ANU) High Resolution X-ray Computed Tomography Facility (Sakellariou et al. 2004) was used to examine the internal structures of the neurocranium, dermal skull and mandible. The ANU-created software Drishti was used to visualise the tomographic data sets.
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000397703: Skull [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
--
Event date
--
Software
Drishti
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Processing Details Field Definitions

Creator
--
Event date
--
Software
Drishti
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 4: IMAGE PROCESSING

Derived Media 000397706: Mandible [CTImageSeries] [CT] was processed to create derived Media 000422117: Mandible [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Alice Clement
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000422117: Mandible [Mesh] [CT] (this media)