Media 000637948: Stained Pelvic Region
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000637948: Stained Pelvic Region
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Team
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000637948
Media type
Volumetric Image Series
Object element or part
stained pelvic region
Object represented
Object taxonomy
Zygaspis quadrifrons
Object organization
Side
--
Orientation
--
Short description
HRXCT scan -- stained pelvic region
Full description
University of Texas High-Resolution X-ray CT Facility Archive
Lewis:
17751_pelvisA: Scans of a stained pelvis of Zygaspis quadrifons (FMNH 17751; Bechuanaland Prot: Kabulabula. Coll: H. Lang. Collector #: 338) for Patrick Lewis of Sam Houston State. Specimen scanned by Jessie Maisano 3 April 2015. Stained in 10% IKI for 2 weeks, then stain diluted by 50% and stained 1 more week.
scan parameters: Xradia. 4X objective, 80kV, 10W, 4s acquisition time, detector 30 mm, source -37 mm, XYZ [-502, 28630, 831], camera bin 2, angles ±180, 1261 views, no filter, dithering, no sample drift correction. End reference (45 frames, each for 4s). Reconstructed with center shift 2, beam hardening 1, theta 94, byte scaling [-40, 550], binning 1, recon filter smooth (kernel size = 0.5). Total slices = 890.
17751_pelvisA.rcp: Xradia recipe with scan parameters.
16bit: 16bit TIFF images reconstructed by Xradia Reconstructor. Voxels are 3.72 microns.
Creator
Jessie Maisano
Date created
April 03, 2015
Date uploaded
June 18, 2024
FILE OBJECT DETAILS Field Definitions
File name
16bit.zip
File format(s)
ZIP archive, TIFF
File size
1.07 GB
Image width
884
Image height
866
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
3.720000
Y pixel spacing
3.720000
Z pixel spacing
3.720000
Pixel spacing units
Um
Slice thickness
--
Number of images in set
890
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
0
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Field Museum of Natural History
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
Data acquired for Patrick Lewis. Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
fmnh:amphibians and reptiles:17751
was imaged to create
this media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Jessie Maisano
Event date
April 03, 2015
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
Media produced by this event on MorphoSource
Media 000637948: Stained Pelvic Region [CTImageSeries] [CT] (this media)