Media 000013212: Braincase
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000013212: Braincase
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000013212
Media type
Volumetric Image Series
Object element or part
braincase
Object represented
Object taxonomy
Trionyx kyrgyzensis
Object organization
Side
--
Orientation
--
Short description
zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: braincase
Creator
--
Date created
--
Date uploaded
May 31, 2016
FILE OBJECT DETAILS Field Definitions
File name
16bitrot.zip
File format(s)
ZIP archive, TIFF
File size
1.53 GB
Image width
1024
Image height
1024
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.040070
Y pixel spacing
0.040070
Z pixel spacing
0.040070
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,199
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Zoological Institute of the Russian Academy of Sciences
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
B. Edward Bensinger, 3d, B.A. 1951, Prize
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Natasha Vitek provided access to these dataoriginally appearing in , the collection of which was funded by the B. Edward Bensinger, 3d, B.A. 1951, Prize. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
zin:PHT-F67.218
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1400
Voltage
200
Power
--
Amperage
0.2
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000013212: Braincase [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000013212: Braincase [CTImageSeries] [Etc] (this media)