Media 000013213: Braincase
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000013213
Media type
Mesh
Object element or part
braincase
Object represented
Object taxonomy
Trionyx kyrgyzensis
Side
--
Orientation
--
Short description
segmented braincase surface
Full description
Migrated MorphoSource 1 Media File Title: segmented braincase surface Migrated MorphoSource 1 Media Group Title: braincase
Creator
--
Date created
--
Date uploaded
May 31, 2016

FILE OBJECT DETAILS Field Definitions

File name
trion_edit3.ply
File format(s)
PLY
File size
182 MB
Points
2388020
Polygons
4776154
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
24.803, 16.909, 33.859
Centroid coordinates
16.423, 19.628, 16.881
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Zoological Institute of the Russian Academy of Sciences
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
B. Edward Bensinger, 3d, B.A. 1951, Prize
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Natasha Vitek provided access to these dataoriginally appearing in , the collection of which was funded by the B. Edward Bensinger, 3d, B.A. 1951, Prize. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object zin:PHT-F67.218 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1400
Voltage
200
Power
--
Amperage
0.2
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000013212: Braincase [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000013212: Braincase [CTImageSeries] [Etc] was processed to create derived Media 000013213: Braincase [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000013213: Braincase [Mesh] [Etc] (this media)